Solid State Voltage Stabiliser
In
India, we have a large power distribution system with heavy
distribution losses and variations in industrial/ domestic load. This
results in voltage variations that may damage electrical/ electronic
appliances like light, fan, television, mixer-grinder, air-conditioner,
heater, water pump, toaster, etc.
Here, we describe how to make a solid-state voltage stabiliser that does not use electromechanical relays and is suitable for most purposes. Key features of the solid-state voltage stabiliser are:
Here, we describe how to make a solid-state voltage stabiliser that does not use electromechanical relays and is suitable for most purposes. Key features of the solid-state voltage stabiliser are:
1. Wide range of voltage variation from 120 V to 280 V
2. Only two settings are required low voltage and high voltage
3. Stabilised output of 220V4. Compact size
5. Silent operation and no relay chattering sound
6. Bar graph LED voltage indicator
7. Low/high voltage indicator and cut-off protection
The block diagram of a solid-state voltage stabiliser is shown in Fig.1.
Fig.1:Block diagram of solid-state voltage stabiliser
The circuit diagram comprises following four sections:
1. Analogue voltage to digital step changer
2. Isolated solid-state power relay
3. Control power supply unit
4. Mains transformer
Fig.2:Circuit diagram of voltage stabiliser
All the 10 outputs of IC1 that are used to lit the LEDs are also fed as inputs to dual decoder/demultiplexer CD4556. CD4556 is used for converting analogue voltage to digital steps to ensure that, at a given time, only one tapping of mains transformer gets input supply voltage from mains. In all conditions only one step can be active as per analogue input voltage.
Assume the first condition when the mains voltage is less than the lower set value. All the output pins (1, 18, 17, 16, 15, 14, 13, 12, 11, 10) of IC1 will be high. IC3(A) will be disabled and no step will be selected (means low volt 16, 15, 14, 13, 12, 11, 10) of IC1 will be high. IC3(A) will be disabled and no step will be selected (means low voltage cut-off).
As
the mains voltage increases to more than the lower set value, LED1 of
the bar graph voltmeter glows as pin1 of IC1 is low and all other
outputs pins are high. In this condition IC2(A) is enabled because input
E (pin 1) is low. As inputs A0 and A1 of IC2(A) are high, out put Q3
goes low. This is step 1 of step charger.
When voltage increases, input A0 of IC2(A) goes low and its output Q2 also goes low. This is Step 2 of step changer.
Both these outputs are combined with 1N4148 diodes and given to cathode pin of internal LED of IC7 (MOC3011). As internal LED of IC7 glows, TRIAC1 conducts and provides AC mains to tapping ‘A’ of mains transformer X2.
When voltage increases further, both inputs A0 and A1 of IC2(A) go low, while both of its outputs go high , and TRIAC1 goes off. Input A1 and output Q2 of IC2(A) generate enable input E for IC2(B) with the help of set and reset input pins (S and R) of flip-flop IC5(A) (CD4013). Pin 1 of IC5(A) provides low signal to enable input E of IC2(B) and output Q3 of IC2(B) goes low. This is Step 3 of step changer. Similarly, other conditions work in the same manner (see Table).
The number of tappings for transformer X2 and the number of solid-stat relays to be used depend on the voltage range to be covered. If the minimum voltage can drop to 100 volts and the maximum could rise to 300 volts, we need to cover 200 volts deviation. This can be managed either through ten tappings with 20V difference or just five tappings with 40V difference between each.
Control power supply. Circuit diagram of control supply circuit is shown in Fig. 3. The 230V, 50Hz AC mains is stepped down by transformer X1 to deliver a secondary output of 24V, 500 mA. The transformer output is rectified by full-wave rectifier BR6, filtered by capacitor C9 and regulated by IC 7812 (IC12), which provides a 12V DC output. C10 and C11 provide further filtering. LED1 acts as the power indicator. Resistor R23 acts as a current limiter.
When capacitors used in the output are more than 10 μF, it is necessary to protect the regulator IC using diode (in this case, D11), in case their input is short to ground. Unregulated DC supply voltage is used for input sensing by IC1 for controlling the steps of mains transformer through solid-state relays.
Fig.3: Power Supply
Mains transformer. The mains transformer used here is an auto-transformer with tappings of 120V, 152V, 184V, 216V, 248V and 281V, respectively (as shown in Fig. 2). All the tappings are connected with the voltage control solid-state relays to provide respective voltages. The tap at 216 volts is connected directly to the output.
Construction
1. Use a variable voltage transformer having 0 to 300 volts range and a digital voltmeter (3½-digit) for measurement of mains power supply.
2. Connect this solid-state voltage stabiliser with variable transformer starting from zero volts setting. Increase voltage slowly from 0 to 120 volts
3. Set variable voltage transformer output of 120 volts with the help of digital voltmeter
4. Set low voltage setting preset VR2 of IC-LM3914 so that only LED1 glows
5. Now set the transformer at 281 volts with the help of digital voltmeter
6. Set high voltage setting preset VR1 of IC1 so that all LEDs from LED1 through LED10 can glow
7. Set the transformer at 184 volts and check the LEDs
8. Set the transformer at 248 volts and check the LEDs
9.
Move variable transformer from 120 to upside and check solid-state
relay output one by one with the help of a test lamp of 220V, 40W. Also
see table of CD4556.
10. Connect mains transformer tappings to solid-state relays with great care at proper tappings.11. Now connect digital voltmeter to output socket and check the voltage with variable transformer from 120V ~ 281. the output should remain 220V
12. Connect test lamp as a load and check voltage variation. Now the solid-state voltage stabiliser is ready for use with a load of 1KVA.
note:-Male and female pin type power connectors may be used to connect mains transformer tapping with solid-state relays on PCB. Bar graph LED voltmeter connection also provides male and female pin connection from PCB to front panel of the stabiliser.
No comments: